In house design and BIM
50 design engineers, BIM coordinators and modellers produce coordinated shop drawings for every project.

Industries we serve
MEPF, civil works and building intelligence for data centres. Every system between the utility intake and the rack, from one contractor.
What we deliver in a data centre
Engineered, installed and commissioned by one contractor.
Scroll to move through the building

01HVAC
Chillers and cooling towers, primary and secondary pumping, N+1 and 2N distribution, thermal energy storage, PICV balancing, sectional isolation and cross ties for concurrent maintainability.

02HVAC
CRAH and PAC units, in row cooling, aisle containment, rear door heat exchangers, liquid cooling ready paths with CDU integration, zoned leak detection.

03Electrical
33, 22 and 11 kV HT systems, transformers, LT switchgear, bus ducts, 2N A and B paths, UPS and battery rooms with hydrogen sensing, DG synchronisation, HSD fuel systems.

04Plumbing
Water supply and make up water for the cooling plant, floor drainage for data halls and technical rooms, sanitary installations, water treatment and rainwater harvesting.

05Fire
Very early smoke detection, double interlock pre action sprinklers, clean agent suppression, hydrants, high pressure water mist, foam, fire rated compartmentation.

06BMS and ELV
PLC plant control, BMS supervision, electrical power monitoring and DCIM interfaces on open protocols. Access control, CCTV, water and liquid leak detection, public address, structured cabling and fire alarm integration.

07Civil
Raised floors, partitions and false ceilings in data halls, equipment plinths and foundations, trenches, fire stopped penetrations.

08All services
Factory and site acceptance, L1 to L5 commissioning, load bank testing, integrated systems testing of failure scenarios, operator witnessed records.
Our experience
Eight active projects across five locations and two completed references. Each opens its own page, with the project overview and the scope of work by service.
3 active projects20 MW, Floors 6 to 9 of a live colocation facility
Learn more
2 active projects700+ MW campus, Chandanvelly, scalable to 1.4 GW
Learn more
Active48 MW, Hyperscale, high density
Learn more600 MW, Potential IT load of the Hyderabad campus
Learn more
Active21 MW campus, Tier III, about 450,000 sq ft of IT space
Learn more
Completed28.4 MW campus, 11 acres, Tier III
Learn more
CompletedServer rooms and incubation space
Learn moreWhy Unique Engineers
Eight things clients get from us in addition to the installation itself. The first five each have a page of their own.
Spools, riser sets, valve stations and pump skids built and tested off site, then lifted in when the workfront is ready.
Learn moreOur own yard in Gurugram cuts, joins, tests and tags assemblies before they reach site.
Learn moreEach repeating floor arrives as one tagged kit and is installed in one fix, with nothing cut at height.
Learn moreAI copilots for tender extraction, method statements, contract review and meeting synthesis, signed off by the accountable engineer.
Learn moreBMS and controls delivered in house, with AI for predictive maintenance and energy savings after handover.
Learn more50 design engineers, BIM coordinators and modellers produce coordinated shop drawings for every project.
MEPF, BMS, solar and civil works from one organisation, with a single point of accountability.
Every order placed at head office on a rate library and annual rate contracts, with standing OEM relationships.
Start a conversation