Skip to content
Unique Engineers.

Solar & Renewable

Ground-Mounted Solar.

Utility-scale and captive ground-mounted PV plants on fixed-tilt or single-axis tracking structures with HT evacuation.

Systems & scope

What this covers.

Civil & foundations

Concrete pier, ground screw or rammed pile foundations for module mounting structures. Drainage, site grading and access roads.

Fixed-tilt & tracking

Fixed-tilt structures sized to site latitude. Single-axis tracking systems where the additional yield (typically 15-20%) justifies the capex.

HT evacuation

Inverter step-up via 33 kV / 11 kV transformer, HT switchgear, and evacuation line to the DISCOM's substation. Protection coordinated with grid impedance.

Engineering approach

Site assessment includes soil bearing capacity (for foundation type), irradiance modelling against multiple TMY datasets, and grid feasibility with the local DISCOM. The energy yield estimate drives the financial model.

Foundation type — concrete pier, ground screw or rammed pile — is chosen against soil condition and project economics. Mounting structures are galvanised steel; modules are mono-PERC with 25-year warranty.

Back to Solar & Renewable

Start a conversation

Let’s discuss your project.