Skip to content
Unique Engineers.

HVAC

Low Side.

Air-side equipment — AHUs, FCUs, VRF, terminal units, ducting and the diffusion strategy that delivers conditioned air to the space.

Systems & scope

What this covers.

Air handling units (AHUs)

Floor-mount and ceiling-suspended AHUs with chilled-water or DX coils, single or dual-fan, plug-fan or housed-fan, with full filtration train. In-house AHU manufacturing capability since 2005.

Fan coil units (FCUs)

Concealed and exposed FCUs for guest rooms, offices, and zone-level conditioning. EC-motor selection where part-load and acoustics matter; standard PSC where simple control is sufficient.

VRF / VRV systems

Variable refrigerant volume systems for offices, retail and hospitality where chilled-water plant is over-specified. Heat-recovery topologies where simultaneous heating and cooling exists.

Dedicated outdoor air systems (DOAS)

DOAS / make-up air units sized to ASHRAE 62.1 ventilation rates with energy recovery (sensible or enthalpy) where climate makes the payback work.

Ducting & terminal devices

Galvanised steel and pre-insulated aluminium ducting, fabricated to SMACNA, leak-tested to class A/B/C. Diffusers, grilles and VAV terminals selected for throw, drop, noise and architectural integration.

Fan filter units (FFUs)

Ceiling-mounted FFUs for cleanroom and laboratory zones with HEPA H13/H14 terminal filtration. 13,656 FFUs installed on the SAEL Jewar project alone.

Engineering approach

Air-handling units are selected from the heat-load calculation, the supply-air temperature schedule, and the room's acoustic limit. Coil rows, face velocity and bypass factor are picked deliberately — not from a default AHU configurator. DX, chilled-water and dual-coil arrangements coexist on most projects, sized for their loads.

Ducting is routed in Revit (LOD 400) against the structural and architectural envelope, with all clashes resolved before fabrication release. Duct cross-sections balance pressure-drop budget against space constraint. Site installation is leak-tested to SMACNA class A/B/C as the spec demands.

In delivery

Related project experience.

Semiconductor/ Manufacturing · ₹650 Cr

Foxconn | Apple Manufacturing Campus

Bangalore, Karnataka

View case study
Solar Cell Manufacturing · ₹300 Cr

SAEL Solar Cell Manufacturing

Jewar, NCR

View case study
Office Building · ₹250 Cr

Common Central Secretariat & Executive Enclave

New Delhi, Delhi

View case study
Back to HVAC

Start a conversation

Let’s discuss your project.