Civil & Interior
Façades & Envelope.
Unitised and stick-system curtain walls, ACP cladding and structural glazing sealed against the building envelope.
Systems & scope
What this covers.
Unitised curtain walls
Factory-glazed, factory-sealed panels lifted to the slab edge as complete units. Faster install, tighter quality, fewer site joints.
Stick-system glazing
Site-assembled mullion-and-transom systems for buildings with complex geometry or constrained access where unitised lifts aren't feasible.
ACP & metal cladding
Aluminium composite panels, zinc and copper rainscreen systems on through-fastened or hidden-fixing rails. Fire-rated cores per local code.
Engineering approach
Performance is verified on a full-scale mock-up before mass production: AAMA 501 water penetration, AAMA 502 field hose test, and structural deflection per ASCE 7. Thermal performance is measured to ISO 12567.
Anchorage drawings are stamped by the structural team and verified against the as-built slab edge — corrections are detailed at the bracket, never at the panel.